Features
|
Benefits
|
Applications
|
Specifications |
Electrical
Ratings Compliance
| Product Type | DI Water Vapor Delivery Module |
| Differentiator | Ultra High Purity DIW Vapor Highest Flow Accuracy Compact Design EtherCAT interface |
| Vaporization Method | Vapor Draw |
| Fluid Type | UHP DI Water |
| Flow Range (Full Scale Capacity) | 3000 sccm |
| Turndown Ratio | 20:1 |
| Response Time | <2 sec |
| Accuracy | ±1% SP @ >10% FS ±0.2% FS @ 5 – 10% FS |
| Linearity | ±0.5% of FS |
| Repeatability | <±0.2% FS |
| Flow Temperature Coefficient | 0.05% per °C zero and span |
| Valve Shut Down | Normally Closed Valve: <0.5% FS |
| Analog Communication | 0 to 5-24 Vdc |
| Digital Communication | EtherCAT via dual RJ-45 jacks Diagnostic (RS485) via microUSB |
| Electrical Connection | 208-230 Vac, 50/60 Hz, 290 Watts Nominal (tank heater) ± 15 Vdc, ± 5% @ 1.2 amp (MFC heater and PCBA) |
| Status Lights | Zero Device Ready Warm Up Device Fault ECAT Error EtherCAT Run EtherCAT Link Active |
| Diagnostic / Service Port | RS-485 via microUSB |
| Fittings | Outlet Vapor: 1/2″ Female VCR Inlet DI Water: 1/4″ Male VCR or Tube Compression DI Water Drain: 1/8″ Instant Tube Fitting |
| Mounting Orientation | Vertical with DIW inlet fittings down |
| Max Pressure | Vapor Outlet: 200 torr |
| Supply Pressure | DI Water: 10 – 40 psig N2 Purge: 10 – 40 psig |
| Ambient Temperature Range | 15 – 45°C |
| Internal Volume | 0 to 95% RH, non-condensing |
| EMC | Electromagnetic Compatibility (EMC): Fully Compliant to Directive 2004/108/EC (EN: 61326-1:2013) Low Voltage Directive (LVD): Fully Compliant to Directive 2006/95/EC (EN: 61010-1:2010) |
| Environmental Compliance | RoHS Directive (2011/65/EU) REACH Directive EC 1907/2006 SEMI E54.20-1108: Standard for Sensor/Actuator Network Communication for EtherCAT® |