Features
|
Benefits
|
Applications
|
Specifications |
Ratings Diagnostics Compliance
| Product Type | Pressure Controller |
| Differentiator | Wide Pressure Measurement & Control Range |
| Performance | |
| Flow Range (Full Scale Capacity) | .003 – 50 lpm |
| Accuracy | Pressure
±0.25% of Transducer FS (FS > 300 psia) Flow N/A |
| Repeatability | 0.20% SP |
| Flow Temperature Coefficient | ±0.1% of FS per °C |
| Max Pressure | Up to 50 lpm: 1500 psia / 100 bara Up to 10 lpm: 4500 psia / 310 bara |
| Pressure Control Range | Turndown 100:1 for FS from 1-50 lpm 50:1 for all other FS flows |
| Response Time | System dependent |
| Temperature Range | 0 – 65°C (32 – 149°F) |
| Leak Integrity | 1 x 10-9 atm cc/sec He |
| Mechanical | |
| Seal Material | Elastomer |
| Valve Options | Normally Closed Normally Open |
| Wetted Materials | 316L Stainless Steel High Alloy Stainless Steel Viton® fluroelastomers Optional: Buna-N, Kalrez®, Teflon®/Kalrez®, and EPDM |
| Electrical | |
| Analog Communication | 0-5 V, 1-5 V, 0-10 V, 0-20 mA, 4-20 mA |
| Digital Communication | DeviceNet™ Profibus® RS-485 |
| Electrical Connection | DeviceNet™ 1 x M12 with threaded coupling nut (B)Profibus® 1 x 15-pin Male Sub-D 1 x 9-pin female Sub-DRS485 1 x 15-pin Male Sub-D, (A) |
| Power Supply / Consumption | Analog / Profibus® / RS485 Valve Orifice > 0.032″: 8 Watts Valve Orifice ≤ 0.032″: 5 Watts Without Valve: 2 WattsDeviceNet™ Valve Orifice > 0.032″: 10 Watts Valve Orifice ≤ 0.032″: 7 Watts Without Valve: 4 Watts |
| Diagnostic Capability | Available |
| Status Lights | MFC Health Network Status |
| Alarms | Control Valve Output Network Interruption |
| Diagnostic / Service Port | RS485 via 2.5mm jack |
| Certifications/Approvals | ATEX IECEx |
| EMC | EMC Directive 2004/108/EC CE: EN61326-1: 2006 |
| Environmental Compliance | RoHS Directive (2011/65/EU) |
| Size | Medium |
| Price | $$$ |