ADVANTAGE
|
APPLICATIONS
|
CHARACTERISTICS
|
DATA SHEET |
PRESSURE MEASUREMENTELECTRICAL DATAPNEUMATIC DATABUILDING
| FLOW MEASURE | |
| Flow range | Minimum 0 to 20 ml / min and maximum 0 to 2000 L / min (for all ranges see the product catalog) |
| Improved accuracy at 20 ºC |
|
| Resolution | 4 digits on screen |
| Temperature coefficients |
|
| Long-term drift | <1% by year |
| Pressure range | Minimum ± 2 mbar and maximum -1 bar at 14 bar (for all ranges see the product catalog) |
| Accuracy at 20 ºC |
|
| Resolution | 4 digits on screen |
| Temperature coefficients |
|
| Long-term drift | < 1% by year |
| Supply voltage | 24 Vcc ±10% <500 mA |
| Electric connections |
|
| Control inputs | Up to 24 opto-isolated inputs, active by high or low. 5 Vcc at 24 Vdc with 10 k Ω </ b> |
| Control outputs | Up to 32 active outputs per transistor (PNP). 12 Vdc at 45 Vdc, 120 mA (per channel) |
| Compatible media | Clean and dry air or non-corrosive gases |
| Gas temperature in LFE |
0 a 50 ºC |
| Relative humidity of the gas | 0 a 95% not condensed |
| Service pressure | Maximum 10 bar, minimum 5 bar |
| Pressure supplied to the regulator for test | Maximum 6 bar or 35 bar for the option of 30 bar |
| Pneumatic connections |
|
| Working pressure LFE | Maximum static pressure of 4 bar |
| Box | Manufactured in steel, manufacturing option in RACK of 19 ‘3U |
| Dimensions with rack | 482 x 133 x 296 mm (L x A x P) |
| Dimensions | 366 x 147 x 296 mm (L x A x P) |
| Weight | 8 kg ± 0,5 kg (unlaminated) |